35 research outputs found

    Performance of a fully automatic lesion detection system for breast DCE-MRI

    Get PDF
    PURPOSE: To describe and test a new fully automatic lesion detection system for breast DCE-MRI. MATERIALS AND METHODS: Studies were collected from two institutions adopting different DCE-MRI sequences, one with and the other one without fat-saturation. The detection pipeline consists of (i) breast segmentation, to identify breast size and location; (ii) registration, to correct for patient movements; (iii) lesion detection, to extract contrast-enhanced regions using a new normalization technique based on the contrast-uptake of mammary vessels; (iv) false positive (FP) reduction, to exclude contrast-enhanced regions other than lesions. Detection rate (number of system-detected malignant and benign lesions over the total number of lesions) and sensitivity (system-detected malignant lesions over the total number of malignant lesions) were assessed. The number of FPs was also assessed. RESULTS: Forty-eight studies with 12 benign and 53 malignant lesions were evaluated. Median lesion diameter was 6 mm (range, 5-15 mm) for benign and 26 mm (range, 5-75 mm) for malignant lesions. Detection rate was 58/65 (89%; 95% confidence interval [CI] 79%-95%) and sensitivity was 52/53 (98%; 95% CI 90%-99%). Mammary median FPs per breast was 4 (1st-3rd quartiles 3-7.25). CONCLUSION: The system showed promising results on MR datasets obtained from different scanners producing fat-sat or non-fat-sat images with variable temporal and spatial resolution and could potentially be used for early diagnosis and staging of breast cancer to reduce reading time and to improve lesion detection. Further evaluation is needed before it may be used in clinical practice

    NGS WFSs module for MAORY at E-ELT

    Get PDF
    We report on the natural guide star (NGS) wavefront sensors (WFS) module for MAORY, the multi-cojugate adaptive optics (MCAO) system for the ESO E-ELT. Three low-order, near-infrared (H-band), Shack-Hartmann sensors provide fast acquisition of the first 5 modes (tip, tilt, focus, astigmatism) on 3 natural guide stars over a 160 arcsec field of view. Three moderate-order (20x20), visible (600-800 nm), pyramid WFSs provide the slow Truth sensing to correct LGS wavefront estimates of low-order modes. These sensors are mounted onto three R-theta stages to patrol the field of view. The module is also equipped with a retractable, on-axis, high-order (80x80), visible, pyramid WFS for the single-conjugate AO (SCAO) mode of MAORY and MICADO. The visible WFSs share the same 80x80 pyramid WFS design. This choice enables also a MCAO NGS capability. Simulations show that Strehl ratios (SR) over 40% are reached with MCAO and three, 2x2 sub-apertures, NIR low-order WFSs working with H-mag=20 reference stars. In SCAO mode, 90% SR for a 8mag stars with a contrast down to 10-5, and 45% SR for a 16mag star, are achieved

    GIANO and HARPS-N together: towards an Earth-mass detection instrument

    Get PDF
    This article describes the works we are doing for modifying the interface between the high resolution infrared spectrograph GIANO (0.97-2.4 micron) and the TNG telescope, passing from a fiber feed configuration to the original design of a direct light-feeding from the telescope to the spectrograph. So doing the IR spectrograph, GIANO, will work in parallel to HARPS-N spectrometer (0.38-0.70 micron), the visible high resolution spectrograph, thanks to a new telescope interface based on a dichroic window that simultaneously feeds the two instrumentes: this is GIARPS (GIAno and haRPS). The scientific aims of this project are to improve the radial velocity accuracy achievable with GIANO, down to a goal of 1 m/s, the value necessary to detect Earth-mass planets on habitable orbits around late-M stars, to implement simultaneous observations with Harps-N and GIANO optimizing the study of planets around cool stars. The very broad wavelengths range is particularly important to discriminate false radial velocity signals caused by stellar activity. We therefore include several absorption cells with different mixtures of gases and a stabilized Fabry Perot cavity, necessary to have absorption lines over the 0.97-2.4 microns range covered by GIANO. The commissioning of GIARPS is scheduled by the end of 2016

    New Ultra-minimally Invasive Surgical Treatment for Benign Prostatic Hyperplasia: A Systematic Review and Analysis of Comparative Outcomes

    Get PDF
    Context: Benign prostatic hyperplasia (BPH) associated with lower urinary tract symptoms (LUTS) is diagnosed in up to 80% of men during their lifetime. Several novel ultra-minimally invasive surgical treatments (uMISTs) for BPH/benign prostatic obstruction (BPO) have become available over the past 5 yr. Objective: To evaluate the perioperative and functional outcomes of recently introduced uMISTs for BPH/BPO, including Urolift, RezĆ«m, temporary implantable nitinol device, prostatic artery embolization (PAE), and intraprostatic injection. Evidence acquisition: A systematic literature search was conducted in December 2020 using Medline (via PubMed), Embase (via Ovid), Scopus, and Web of Science (registered on PROSPERO as CRD42021225014). The search strategy used PICO criteria and article selection was conducted in accordance with the PRISMA guidelines. The risk of bias and the quality of the articles included were assessed. A dedicated data extraction form was used to collect the data of interest. Pooled and cumulative analyses were performed to compare perioperative and functional outcomes between study groups. A random-effects model using the DerSimonian and Laird method was used to evaluate heterogeneity. Stata version 15.0 software was used for all statistical analyses. Evidence synthesis: The initial electronic search identified 3978 papers, of which 48 ultimately met the inclusion criteria and were included in the analysis. Pooled analysis revealed a uMIST benefit in terms of International Prostate Symptom Score (IPSS; −9.81 points, 95% confidence interval [CI] −11.37 to −8.25 at 1 mo; −13.13 points, 95% CI −14.98 to −11.64 at 12 mo), maximum flow rate (from +3.66 ml/s, 95% CI 2.8–4.5 to +4.14 ml/s, 95% CI 0.72–7.56 at 12 mo), and postvoid residual volume (−10.10 ml, 95% CI −27.90 to 7.71 at 12 mo). No negative impact was observed on scores for the International Index of Erectile Function-5, Male Sexual Health Questionnaire-Ejaculatory Dysfunction bother and function scales (overall postintervention change in pooled median score of 1.88, 95% CI 1.34–2.42 at the start of follow-up; and 1.04, 95% CI 0.28–1.8 after 1 yr), or the IPSS-Quality of Life questionnaire. Conclusions: Novel uMISTs can yield fast and effective relief of LUTS without affecting patient quality of life. Only RezĆ«m, UroLift, and PAE had a minimal impact on patients’ sexual function with respect to baseline, especially regarding preservation of ejaculation. Patient summary: We reviewed outcomes for recently introduced ultra-minimally invasive surgical treatments for patients with lower urinary tract symptoms caused by benign prostate enlargement or obstruction. The evidence suggests that these novel techniques are beneficial in terms of controlling symptoms while preserving sexual function. Take Home Message: Novel ultra-minimally invasive treatments can yield fast and effective relief of lower urinary tract symptoms without affecting a patient's quality of life

    GIANO-TNG spectroscopy of red supergiants in the young star cluster RSGC3

    Get PDF
    Aims: The Scutum complex in the inner disk of the Galaxy has a number of young star clusters dominated by red supergiants that are heavily obscured by dust extinction and observable only at infrared wavelengths. These clusters are important tracers of the recent star formation and chemical enrichment history in the inner Galaxy. Methods: During the technical commissioning and as a first science verification of the GIANO spectrograph at the Telescopio Nazionale Galileo, we secured high-resolution (R ≃ 50 000) near-infrared spectra of five red supergiants in the young Scutum cluster RSGC3. Results: Taking advantage of the full YJHK spectral coverage of GIANO in a single exposure, we were able to measure several tens of atomic and molecular lines that were suitable for determining chemical abundances. By means of spectral synthesis and line equivalent width measurements, we obtained abundances of Fe and iron-peak elements such as Ni, Cr, and Cu, alpha (O, Mg, Si, Ca, Ti), other light elements (C, N, F, Na, Al, and Sc), and some s-process elements (Y, Sr). We found average half-solar iron abundances and solar-scaled [X/Fe] abundance patterns for most of the elements, consistent with a thin-disk chemistry. We found depletion of [C/Fe] and enhancement of [N/Fe], consistent with standard CN burning, and low 12C /13C abundance ratios (between 9 and 11), which require extra-mixing processes in the stellar interiors during the post-main sequence evolution. We also found local standard of rest VLSR = 106 km s-1 and heliocentric Vhel = 90 km s-1 radial velocities with a dispersion of 2.3 km s-1. Conclusions: The inferred radial velocities, abundances, and abundance patterns of RSGC3 are very similar to those previously measured in the other two young clusters of the Scutum complex, RSGC1 and RSGC2, suggesting a common kinematics and chemistry within the Scutum complex

    Front-Ends and Phased Array Feeds for the Sardinia Radio Telescope

    Get PDF
    We describe the design and performance of the Front- Ends for the 64-m diameter Sardinia Radio Telescope (SRT). An early science program was completed with SRT in August 2016, following a successful technical and scientific commissioning of the telescope and of its instrumentation. We give an overview of the three cryogenic Front-Ends, covering four bands, that were deployed on SRT during the early science program: P-band (305-410 MHz), L-band (1.3-1.8 GHz), high C-band (5.7- 7.7 GHz) and K-band (18-26.5 GHz). In addition, we describe the cryogenic Front-Ends that are currently under development, among which a seven beam for S-band (3.0-4.5 GHz) a mono-feed for Low-Cband (4.2-5.6 GHz), a 19-element for Q-band (33-50 GHz) and a mono-feed for a 3 mm band. Finally, we describe the development status of a demonstrator of a cryogenic C-band Phased Array Feed (PAF) for potential use at the SRT primary focus

    Image-guided breast biopsy and localisation: recommendations for information to women and referring physicians by the European Society of Breast Imaging

    Get PDF
    Abstract: We summarise here the information to be provided to women and referring physicians about percutaneous breast biopsy and lesion localisation under imaging guidance. After explaining why a preoperative diagnosis with a percutaneous biopsy is preferred to surgical biopsy, we illustrate the criteria used by radiologists for choosing the most appropriate combination of device type for sampling and imaging technique for guidance. Then, we describe the commonly used devices, from fine-needle sampling to tissue biopsy with larger needles, namely core needle biopsy and vacuum-assisted biopsy, and how mammography, digital breast tomosynthesis, ultrasound, or magnetic resonance imaging work for targeting the lesion for sampling or localisation. The differences among the techniques available for localisation (carbon marking, metallic wire, radiotracer injection, radioactive seed, and magnetic seed localisation) are illustrated. Type and rate of possible complications are described and the issue of concomitant antiplatelet or anticoagulant therapy is also addressed. The importance of pathological-radiological correlation is highlighted: when evaluating the results of any needle sampling, the radiologist must check the concordance between the cytology/pathology report of the sample and the radiological appearance of the biopsied lesion. We recommend that special attention is paid to a proper and tactful approach when communicating to the woman the need for tissue sampling as well as the possibility of cancer diagnosis, repeat tissue sampling, and or even surgery when tissue sampling shows a lesion with uncertain malignant potential (also referred to as “high-risk” or B3 lesions). Finally, seven frequently asked questions are answered

    T-REX OU4 HIRES: the high resolution spectrograph for the E-ELT

    Get PDF
    The goal of this unit was to consolidate the project for the construction of the high resolution spectrometer of the E-ELT (HIRES). The task included the development of scientific cases and tools to predict the instrumental performances. From the technical point of view it included several R&D activities in collaboration with highly specialized Italian companies; it culminated with the detailed design of a highly modular instrument based on well established technologies. From the management point of view it lead to the consolidation of a large international consortium that spans over 12 countries and includes most of the European and ESO-related institutes interested in high resolution spectroscopy. This consortium is led by INAF; its formal creation is awaiting the official call by ESO for the phase-A study for the HIRES instrument of the E-ELT

    MAORY: adaptive optics module for the E-ELT

    Get PDF
    MAORY is one of the four instruments for the E-ELT approved for construction. It is an adaptive optics module offering two compensation modes: multi-conjugate and single-conjugate adaptive optics. The project has recently entered its phase B. A system-level overview of the current status of the project is given in this paper
    corecore